Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Artigo em Italiano | MEDLINE | ID: mdl-38639118

RESUMO

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Acidente Vascular Cerebral , Adulto , Humanos , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Prevenção Secundária/métodos , Embolia Paradoxal/etiologia , Embolia Paradoxal/prevenção & controle , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
3.
EuroIntervention ; 20(5): e289-e300, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-37982178

RESUMO

BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-38160130

RESUMO

Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.

5.
JACC Case Rep ; 22: 101978, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37790775

RESUMO

Ischemia with no obstructive coronary artery disease (INOCA) is not an uncommon diagnosis in patients presenting with chest pain who undergo clinically indicated coronary angiography. However, the symptoms reported by patients with INOCA may be heterogeneous, leading to misdiagnosis and undertreatment. Herein we report 3 clinical cases of INOCA misdiagnosis and describe how the cases were reinvestigated following the appropriate diagnostic pathway. (Level of Difficulty: Advanced.).

7.
Int J Cardiol ; 389: 131188, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37453454

RESUMO

BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/cirurgia , Hemorragia/induzido quimicamente , Anticoagulantes/efeitos adversos , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
12.
Psicol. teor. prát ; 25(1): 14535, 19.12.2022.
Artigo em Inglês, Português | LILACS | ID: biblio-1436509

RESUMO

Este estudo teve como objetivo explorar a percepção de alunos de graduação em relação à sua participação em uma intervenção baseada na terapia de aceitação e compromisso (acceptance and commitment therapy[ACT]), para redução da inflexibilidade psicológica (IP) e do estresse em estudantes universitários. Parti­ciparam da pesquisa 21 alunos, de diferentes cursos de graduação, com idade média de 23,4 ± 5,61, sendo 71,4% do sexo feminino e 28,6% do sexo masculino. Os dados coletados nas entrevistas foram submetidos à análise de conteúdo e organizados em quatro categorias: experiência no programa, utilidade, viabilidade e sugestões e processos da ACT. Os resultados possibilitaram identificar que o programa foi uma experiên-cia positiva para os participantes. Além disso, constatou-se que a intervenção foi útil e viável, e possibili-tou que os estudantes desenvolvessem as habilidades necessárias para lidar melhor com as adversidades do dia a dia, sem que precisassem se afastar dos seus valores pessoais.


This study aims to explore undergraduate students' perception of their participation in an intervention, based on acceptance and commitment therapy (ACT), to reduce psychological inflexibility (PI) and stress in undergraduate students. Twenty­one students from different undergraduate programs participated in the research, with an average age of 23.4 ± 5.61, of whom 71.4% were female and 28.6% were male. The data collected in the interviews were submitted to content analysis and organized into four categories: experience in the program, utility, feasibility, and ACT suggestions and processes. The results made it possible to identify that the program was a positive experience for the participants, the intervention was useful and feasible and enabled students to develop the requirements to better deal with the adversities of daily life without departing from their personal values.


Este estudio tiene como objetivo explorar la percepción de los estudiantes de pregrado sobre su participa-ción en una intervención, basada en la terapia de aceptación y compromiso (acceptance and commitment therapy [ACT]), para reducir la inflexibilidad psicológica (IP) y el estrés en los estudiantes de pregrado. En la investigación participaron 21 estudiantes de diferentes carreras, con una edad promedio de 23,4 ± 5,61, de los cuales el 71,4% eran mujeres y el 28,6% hombres. Los datos recolectados en las entrevistas fueron sometidos a análisis de contenido y organizados en cuatro categorías: experiencia en el programa, utilidad, factibilidad y sugerencias y procesos de ACT. Los resultados permitieron identificar que el programa fue una experiencia positiva para los participantes, la intervención fue útil y factible y permitió a los estudian-tes desarrollar los requisitos necesarios para enfrentar mejor las adversidades de la vida diaria, sin apar-tarse de sus valores personales.


Assuntos
Humanos , Masculino , Feminino , Estresse Psicológico , Terapia de Aceitação e Compromisso , Psicologia , Estudantes , Saúde Mental , Pesquisa Qualitativa , Atividades Científicas e Tecnológicas
13.
J Am Heart Assoc ; 11(19): e025944, 2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36172929

RESUMO

The impact of sex on pathophysiological processes, clinical presentation, treatment options, as well as outcomes of degenerative aortic stenosis remain poorly understood. Female patients are well represented in transfemoral aortic valve implantation (TAVI) trials and appear to derive favorable outcomes with TAVI. However, higher incidences of major bleeding, vascular complications, and stroke have been reported in women following TAVI. The anatomical characteristics and pathophysiological features of aortic stenosis in women might guide a tailored planning of the percutaneous approach. We highlight whether a sex-based TAVI management strategy might impact on clinical outcomes. This review aimed to evaluate the impact of sex from diagnosis to treatment of degenerative aortic stenosis, discussing the latest evidence on epidemiology, pathophysiology, clinical presentation, therapeutic options, and outcomes. Furthermore, we focused on technical sex-oriented considerations in TAVI including the preprocedural screening, device selection, implantation strategy, and postprocedural management.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 100(2): 190-198, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35686523

RESUMO

AIM: The impact of Grade III coronary perforations (G3-CP) in the setting of CTO-PCI is not well assessed. METHODS AND RESULTS: We reviewed 7773 CTO-PCI and 98,819 non CTO-PCI performed in 10 European centers: G3 perforation occurred in 87 patients (1.1%) during CTO PCI and 224 patients (0.22%) during non CTO-PCI (p < 0.001). G3-CP involved the CTO segment in 68% of patients and the retrograde channels in 14% of cases. In the CTO PCI group, wire induced G3-CP (50.5% vs. 32.5%, p = 0.02) occurred predominantly when dedicated CTO tapered and highly penetrative wires were used. Intra-procedural and in-hospital death rates were 4.6% vs. 5.8% and 3.6% vs. 7.5% respectively for CTO PCI and non-CTO PCI groups (p = NS). At a median follow up of 24 months, the overall mortality and MAE were respectively 7.8% and MAE 19% without difference among groups. CONCLUSIONS: We showed similar in-hospital and long-term outcomes when G3 perforations occurred during CTO PCI and non CTO-PCI.


Assuntos
Doença da Artéria Coronariana , Oclusão Coronária , Traumatismos Cardíacos , Intervenção Coronária Percutânea , Lesões do Sistema Vascular , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Mortalidade Hospitalar , Humanos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/terapia
16.
Cardiovasc Revasc Med ; 43: 1-6, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35690553

RESUMO

BACKGROUND: Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are generally younger and have a long life expectancy. Therefore, transcatheter bioprostheses durability appears of critical importance. Aim of the present study is to evaluate mid-term outcomes of TAVI in a high-volume single center cohort. METHODS: We analyzed all consecutive patients (n = 408) who underwent transfemoral TAVI at a single, high-volume center, between 2007 and 2014. Study objectives were all-cause death and bioprosthetic valve failure (BVF) at long term follow-up. Structural valve deterioration (SVD), BVF and valve-related death were defined according to current international standards. Follow-up was performed by in person visit and transthoracic echocardiography, which was obtained only in a minority of patients, or phone call as per patient preference. RESULTS: At a median follow-up of 1821 days, overall mortality was 64.5%, with cardiovascular disease accounting for roughly half of total deaths. Valve-related deaths occurred in 10 patients. Seventeen patients were diagnosed with BVF, and 15 required repeat intervention. Moderate and severe SVD were observed in 10 and 7 patients, respectively. In the subgroup of patients with echocardiographic mid-term follow-up (n = 76), no significant increase of transprosthetic gradients nor increase of significant regurgitation was detected. CONCLUSION: In the present unselected, all-comers cohort, TAVI bioprostheses appeared to have excellent durability at long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Eur Heart J Suppl ; 24(Suppl C): C233-C242, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35602251

RESUMO

Recent evidence has shown that transcatheter heart valve (THV) anchoring in bicuspid aortic valve (BAV) patients occurs at the level of the raphe, known as the LIRA (Level of Implantation at the RAphe) plane. Our previous work in a cohort of 20 patients has shown that the delineation of the perimeter and device sizing at this level is associated with optimal procedural outcome. The goals of this study were to confirm the feasibility of this method, evaluate 30-day outcomes of LIRA sizing in a larger cohort of patients, assess interobserver variation and reproducibility of this sizing methodology, and analyse the interaction of LIRA-sized prostheses with the surrounding anatomy. The LIRA sizing method was applied to consecutive patients presenting to our centre with raphe-type BAV disease between November 2018 and October 2021. Supra-annular self-expanding THVs were sized based on baseline CT scan perimeters at the LIRA plane and the virtual basal ring. In cases where there was discrepancy between the two measurements, the plane with the smallest perimeter was considered the reference for prosthesis sizing. Post-procedural device success, defined according to Valve Academic Research Consortium-2 (VARC-2) criteria, was evaluated in the overall cohort. A total of 50 patients (mean age 80 ± 6 years, 70% male) with raphe-type BAV disease underwent transcatheter aortic valve replacement (TAVR) using different THV prostheses. The LIRA plane method appeared to be highly successful (100% VARC-2 device success) with no procedural mortality, no valve migration, no moderate-severe paravalvular leak, and low transprosthetic gradients (residual mean gradient 8.2 ± 3.4 mmHg). There were no strokes, no in-hospital or 30-day mortality, and an incidence of in-hospital pacemaker implantation of 10%. Furthermore, measurement of the LIRA plane perimeter was highly reproducible between observers (r = 0.980; P < 0.001) and predictive of the post-procedural prosthetic valve perimeter on CT scanning (r = 0.981; P < 0.001). We confirm the feasibility of supra-annular sizing using the LIRA method in a large cohort of patients with high procedural success and good clinical outcomes at 30 days. Application of the LIRA method optimizes THV prosthesis sizing in patients with raphe-type BAV disease.

SELEÇÃO DE REFERÊNCIAS